Call Us: 1 (844) 692-6324 | Email: info@trinahealth.com

Method of Therapy

Artificial Pancreas Treatment (APT) is a process which promotes the normalization of carbohydrate metabolism in diabetic patients. APT affects multiple organs, especially muscle, retina, liver, kidney, and nerve endings. The process involves the administration of insulin pulses similar to those found in the portal circulation of normal humans using the Bionica Microdose infusion device which is FDA labeled for this treatment. The process is monitored by frequent glucose levels and metabolic measurements. APT is done over 1-hour periods with a rest period between each session for three courses each day of treatment. Typically, APT is performed on a weekly or bi-weekly basis following the first week of two back-to-back daily sessions.

Initial Clinical Assessment

Patients report to the clinic between 7:00 am and 8:30 am for the initial clinical assessment to perform the following:

  • Capture vital signs.
  • Determine initial glucose level.
  • Review medications.
  • Assess patient’s overall condition.
  • Establish an intravenous (IV) line.

APT Treatment Session

  • U / kg of Insulin, pulsed at 10 pulses/hour over 1 hour is administered by the Bionica Microdose specialty pump programmed for the concentration, frequency and duration of pulses, and rest intervals.
  • The metabolic measurement is performed at the beginning and end of each one hour treatment to measure success of treatment and adjust the amount of insulin and glucose. Glucose levels are taken every 30 minutes or more frequently as medically indicated in patients with a tendency for hypoglycemia.
  • Oral carbohydrates are given to keep blood glucose over 100 mg/dl and to increase metabolic measurement. Approximately 100 g of glucose is given, (400 cal.)
  • There is a rest period of 40 minutes to one hour between treatments in order to stabilize blood glucose levels.
  • This cycle is repeated twice more in a single treatment day.
  • Patient is evaluated after the session and discharged when stable.
Back to Top